Triplett 9007-A User Manual

Page 25

background image

25

7.2 Power Button and Auto Power Off:

Turn on the 9007-A by pressing the yellow power

button

. Press it again to turn the meter off.

The 9007-A has Auto Power Off. This feature automatically

turns the meter off 10 to 15 minutes after it was turned on.......

thereby extending battery life.

7.3 DC Voltage Measurement:

WARNING!

If the magnitude of the voltage to be measured is unknown, always

start by setting the meter to the highest range, and then to lower

ranges, until a satisfactory reading is obtained.

Do not rotate the RANGE switch with the input applied to the meter.

If the input voltage is higher than 600VDC (CAT I, CAT II, or CAT

III), or 600V DC (CAT III), do not attempt to measure!

Use Caution when measuring voltages above 50V DC.

7.3.1 Connect the black test lead to the COM jack and the red

test lead to the input jack indicated as

on the “Front

Panel” drawing on page 22