beautypg.com

Tri Tool 765RVC Hyrdaulic Power Supply User Manual

Page 8

background image

8

TRI TOOL INC.

92-0306 : Rev. 140715

WARNING:

NOTE:

Model Designations

P/N

with Kit No.

Input Voltage

01-0765RVC

05-0146

480 VAC

05-0147

380 VAC

05-0148

240 VAC

Electrical Control Features

Magnetic starter with a 24 VAC starting coil and Overload Protection Circuit Breaker.

Phase sensor to prevent reverse rotation of the motor, which can damage the Hy-

draulic Pump.

The unit is controlled with a remote Pendant, which provides Stop/Start functions,

Variable Volume Control, and a Forward/Neutral/Reverse Control.

The Flow Direction Control is released in the neutral and forward position with

reverse not released and restricted to only supply 25% of the forward flow.

If the power supply has been shut-off with the Stop Button, the Variable Vol-

ume Control must be returned to the zero to start up.

The Pendant is supplied with a 20’ (6 m) cable that connects to the Control

Box.

The addition of extension cables will add up to 200’ (61 m).

Hydraulic Characteristics

Variable Volume

0 gpm (0 L/s) to 15 gpm (.94 L/s)

Operation below 3 gpm (.2 L/s) is not recommended.

The pump capacity is actually 0 gpm (0 L/s) to 22 gpm (10 L/s), however,

operating pressure must be limited to 1000 psi (6895 kPa) at flow over 15

gpm (.94 L/s) to avoid overloading the motor.