beautypg.com

Pendant check procedure – Tri Tool 765RVC Hyrdaulic Power Supply User Manual

Page 18

background image

18

TRI TOOL INC.

92-0306 : Rev. 140715

WARNING:

PENDANT CHECK PROCEDURE

Test the Model 765 RVC remote control pendant functions using an ohm meter by

doing the following:

Field tests can also be made for all functions except for the volume control

using a continuity test meter.

All tests are to be done with the Pendant disconnected from the power supply

and through the pins of the connector.

Do Not Disconnect or Connect the Pendant from the power supply with the

primary power connected. A fuse may blow.

To Verify the Motor ‘Start/Stop’ Functions

Either a Continuity or Ohm meter may be used for this series of checks.

Connect the meter to pins A and B.

Set the volume control to ‘Zero’ and the ‘Start/Stop’ switch to the ‘Start’ position. The

meter will show an ‘Open’ circuit (infinite resistance).

Depress and hold the ‘Start’ switch (momentary contact switch) and the meter will

change from an ‘Open’ circuit to a ‘Closed’ circuit (resistance less than 1 ohm).

While holding the ’Start’ switch down rotate the volume control clockwise (off the

‘Zero’ setting).

The meter will indicate a change from a ‘closed’ circuit to and ‘open’ circuit.

Return the Volume Control to the ‘Zero’ position and while still holding the ‘Start’

switch down, depress the ‘Start/Stop’ switch.

The meter will change from a ‘Closed’ circuit to an ‘Open’ circuit with the Start’

switch depressed.

Connect the meter to pins ‘B’ and ‘C’.

Set the ‘Start/Stop’ switch in the ‘Start’ position.

The meter should show a ‘Closed’ circuit.