Check the Phase Monitor lights.

If the green light is lit the power phasing is correct and

you may proceed with voltage sensitivity level adjust-

ment.

If the red light is lit; either the sensitivity level is too low or

the phasing is incorrect to provide clockwise rotation of

the motor.

Rotate the sensitivity adjustment a full rotation counterclockwise (low

voltage).

If the red light turns off and the green light turns on the phasing

is correct for clockwise rotation of the motor.

If the red light does not turn off the phasing is incorrect.

Reverse two (2) of the power leads to the line connection terminals to

change the motor rotation direction.

Verify that the green light is now lit.

Sensitivity Adjustment

Adjust the sensitivity by rotating the adjustment clockwise towards the ‘high’

setting until the green light turns off and the red light turns on.

Rotate the adjustment counterclockwise 1/8 of a turn or until the green light

turns on.

If the line voltage is subject to frequent small voltage drops, it may be

necessary to lower the sensitivity by an additional 1/8 turn to prevent

random trips.

If any of the leads in the Phase Monitor circuit wires have been

inadvertently disconnected, the rotation direction must be checked to

ensure proper clockwise rotation.

Remove the inspection cover on the Motor to Pump Adapter to provide visual

inspection of the shaft coupling.

Set the Flow Direction control to neutral, the Volume control to zero and pull

the Stop button to the up position.