Model 765 RVC Hydraulic Power Supply

92-0306 : Rev. 140715

Ensure that the connections are solid and the nuts and bolts and well

insulated.

At least four layers of electrical tape must cover the wire ends and connecting

bolts.

The field winding ends are located in the small box on the side of the motor.

Overload Relay

The overload relay is mounted directly to the magnetic starter in the control

box.

The relay or circuit breaker provides over heat protection by killing the motor if

it starts to draw excessive amperage.

Install a 40-ampere range relay for 240 VAC Three (3) Phase Power and set

the variable amperage slide switch to 40 amps (P/N 70-0111).

Install a 20-ampere range relay (P/N 70-0690) for 460 VAC, Three (3) Phase

power and set the amperage to 20 amps.

Control Voltage Transformer