14

TRI TOOL INC.

92-0306 : Rev. 140715

CAUTION:

NOTE:

MAINTENANCE

Hydraulic Filter

Change the Hydraulic Filter after every 1000 hours of use (max.) or at any time the

visual clogging indicator on the full flow filter indicates contaminated filter.

A small red plug ‘pops up’ when pressure differential becomes excessive.

Turn the Shut-Off Valve off before attempting to change either filter.

Place a drain pan under the filter before attempting to remove the old filter.

Make sure that the Shut-Off Valve is open before starting the unit up.

Change at a higher frequency for extremely dusty conditions.

Oil Shut Off Valve

Filter