92-0306 : Rev. 140715

Problem: There is a loss of air power

The air supply pressure is too low.

The air filter is plugged.

The air line size is insufficient.

The air line is too long.

Problem: There is a loss of hydraulic power

The hydraulic supply pressure is too low.

The hydraulic filter is plugged.

The hydraulic line size is insufficient.

The hydraulic line is too long.

Problem: The tool bit will not reach the work

Incorrect tool blocks are installed for the size of the pipe or tube being

worked on.

Incorrect tool bit is installed.

Problem: The hydraulic motor will not start

The hydraulic power supply is shut off.

The hydraulic motor is damaged and will not run free.