Technical specifications – Thinklogical HDX80 Manual User Manual
Page 13

Revision A
December 2011
5
Technical Specifications
Humidity
5-95% RH, non-condensing
Operating Temperature
0-50° C (32-122° F)
Alarm Relay contacts
Maximum DC: 1A at 30VDC
Maximum AC: 0.3A at 125VAC
Contact resistance maximum: 100 m
Ω
Power Requirements
AC Input: 100-240VAC, 47-63 Hz
Universal AC Power Supply
Technical
Specifications
HDX80
HDX576
Physical Dimensions-
Rack Size
EIA 19” (48.26 cm)
EIA 19” (48.26 cm)
Physical Dimensions-
Height
6 RU 10.50” (26.70 cm)
26 RU 45.5” (115.6 cm)
Physical Dimensions-
Width
17.16” (43.59 cm)
17.19” (43.7 cm)
Physical Dimensions-
Depth
15.32” (16.57” including
card pulls; 42.09 cm)
Depth: 23” (including fiber
management tray)
Power Consumption
Approximately 400 Watts
Fully Loaded
Approximately 1700 Watts
Fully Loaded
Actual Weight
37.1 lbs. (16.83 kg)
132.0 lbs. (59.87 kg)
Shipping Weight
100 lbs. (45.36 kg)
170 lbs. (77.1 kg)
Table 2: HDX Router Technical Specifications