beautypg.com

Tecfluid FLOMID-MX User Manual

Page 19

background image

19

9 TECHNICAL

CHARACTERISTICS


9.1

Power

supply

Supply voltage:

Standard : 220 VAC 50/60Hz, 24 VDC

On order : 240 VAC, 110 VAC, 24 VAC 50/60 Hz


Power consumption:

Less than 10 VA


9.2

User programmable pulse output

Frequency mode: 10 - 1000 Hz

Pulse/unit mode: 0 – 2 Hz (minimum 0.01 pulses / measuring unit)
In pulse / unit mode, the pulse output can be programmed for a 50% duty cycle or for a 65 ms

pulse width.

Potential free opto-isolated bipolar transistor.

Maximum current: 50 mA

Maximum voltage: 30 VDC


9.3

Analog output

Galvanically

isolated.

Range: 4 - 20 mA

Maximum load resistance: 700 Ohm.


9.4

Digital

outputs

Potential free opto-isolated bipolar transistor.

Maximum current: 50 mA

Maximum voltage: 30 VDC

9.5

Reset input

Hardware configurable
Current input : Minimum 2 mA

Maximum 10 mA

9.6

Front panel

4 push buttons. Can be mounted in 4 positions at 90 º.

9.7

Display

LCD 2x16 with backlight (except model with DC power supply).


9.8

General characteristics

Ingress protection: IP67

Maximum working temperature: 50 ºC for the LCD.

60 ºC for the rest of the equipment.


9.9 Directives

This equipment complies with the following EEC directives:
Low voltage (73/23/CEE)

Electromagnetic compatibility (89/336/CEE)