LC- 40 ADF

Level Detector

Series

Instructions Manual

Technical Data
• Mounting: Vertical / Side mounting.
• Fittings: EN 1092-1 DN-65 Flanges
Others on demand
• Minimum liquid density: 0.45 kg/l
• Liquid viscosity: maximum 3.000 mPa.s
• Repeatability: ±3 mm of the level .
• Materials: EN 1.4404 (AISI-316L)
On demand: PTFE, PVC, PP, PVDF
• Electrical housing: Metal alloy aluminium

without copper

• Pressure: PN-16
On demand: PN-40 ... PN-400
• Liquid temperature:
Depends on the material, see page 3
• Ambient temperature range: -20…+40 ºC
• Degree of protection: IP67
• Complies with 97/23/EC Directive

for pressure vessels.

R-MI-LC40ADF Rev.:0 English Version

This equipment is considered as being a
pressure accessory and NOT a safety
accessory as defined in the 97/23/EC
directive, Article 1, paragraph 2.1.3.

Operation

The changes in level are followed by the float
mounted on a pivoted arm.

On the opposite end from the float there is a
sealed permanent magnet which acts on
another magnet, situated in the inside of the
electrical housing, that acts on the limit
switches.

Applications:
• Liquid storage tanks
• Hot water storage.
• Control of steam condensates storage

tanks .

• On-Off of pumps.
• Maximum and minimum level control.