Main Features
•
RoHS compliant
•
Operates as a stand-alone controller or with a computer monitor
•
Bi-directional, solid-state H-bridge operation for both heating and cooling
•
Can be configured to control both high and low voltage thermoelectric (TE) devices:
Single power supply configuration for TE devices with an input voltage range from (12 to 36) VDC
Dual power supply configuration for TE devices with an input voltage range is less than 12 VDC:
o
Controller-circuitry input voltage range from (12 to 36) VDC
o
TE device (H-Bridge) input voltage range from (0 to 36) VDC
•
Maximum 25 A current rating, controls up to 900 W
•
Soft-start features turns the output on slowly, over a one second period
•
Over current shutdown that can be set in 2.5 A increments
•
Open sensor and shorted sensor output shutdown with automatic restart
•
Low Voltage shutdown protects the H-bridge when the control circuitry voltage is less than 12 VDC
•
Pulse width modulation of output at 2700 Hz
•
Computer programmable via RS232 communications port
•
Control temperature of –20 °C to +100 °C using thermistor supplied with controller
•
Control temperature of –40 °C to +250 °C using optional thermistors
•
Proportional (P), Integral (I) and Derivative (D) control that can be selected as P, PI, PD or PID; or Deadband (on/off) with an adjustable
hysteresis
•
Temperature resolution of 0.01 °C or 0.01 °F
•
Control stability of ±0.01 °C or ±0.01 °F (best case, when controlling a cold plate)
•
Set temperature adjustable by several options:
•
Computer set via software/RS-232 communication
•
Remote potentiometer (customer supplied)
•
0 mA to 20 mA current loop
•
0 VDC to 5 VDC adjustable range
•
Differential temperature control (allows control to a programmable temperature difference above or below the temperature of the
second thermistor, if used)
•
MP-2986 Display and Keypad (optional accessory)
•
No computer programming experience required to use the communications software program
(Supplied software is compatible with Windows 7 and Windows 8)
•
Command set is provided so programmers can create their own software interface or embedded controller applications
•
Versatile alarm system:
•
Computer configurable alarms for 25 mA, with a compliance voltage up to 11 VDC
•
Alarm cancel: selectable via computer-software communication or remote contact closure
•
The second sensor input is configurable as a heat-sink over-temperature shut-down
•
Non-volatile memory retention of parameters (1,000,000 write cycles maximum; see command #34 in Appendix C for further details.)
•
Operating temperature range of 0 °C to 60 °C, storage temperature range of -55 °C to +105 °C