SET GAGE CALIBRATION - download gage calibration data to one channel
command: (144 + CHAN),
(S0), (S1), (S2), (S3), (S4), (S5)
response: NONE
SET GAGE ZERO - set gage zero-load condition
command: (176 + CHAN)
response: NONE
SET COEFFICIENTS - define custom resistive sensor linearization coefficients
command: (192 + CHAN),
(A_M0), (A_M1), (A_M2), (A_EXP),
(B_M0), (B_M1), (B_M2), (B_EXP),
(C_M0), (C_M1), (C_M2), (C_EXP)
response: NONE
SET GAGE SPAN - set gage full-load value
command: (208 + CHAN),
(MSB DATA), (LSB DATA)
response: NONE
CALIBRATE 518
command: (224 + CHAN),
(CAL_CODE),
(CAL_DATA_MSB), (CAL_DATA_LSB)
response: (DON’T_CARE)
READ PRODUCT I.D. - read Sensoray product identifier
command: (240), (4), (0)
response: (ProductID_MSB), (ProductID_LSB)
READ FIRMWARE VERSION - return coprocessor firmware version number times 100
command: (240), (5), (0)
response: (Version_MSB), (Version_LSB)
HIGH SPEED MODE - enter high speed mode
command: (240), (8), (0)
response: NONE