beautypg.com

Seaward Power Clamp User Manual

Page 29

background image

28

(9) Resistance & Continuity & Diode :

Function

Range

Accuracy

Resistance

999.9 Ω

± (1.0% + 5dgt)

9.999 kΩ

± (1.0% + 3dgt)

99.99 kΩ

Continuity

999.9

± (1.0% + 5dgt)

Diode

0.40~

0.80V

±

0.1V

Overload protection : 1000V

rms

Max. Test Current : Approx. 0.5mA.
Maximum Open Circuit Voltage for Ω, #: Approximate 3V
Maximum Open Circuit Voltage for diode : Approximate ±1.8V
Continuity Threshold : <30Ω Beep On.

100Ω Beep OFF.

Continuity Indicator : 2 KHz Tone Buzzer
Continuity response time : < 100ms.


(10) Capacitance :

Function

Range

Accuracy

Capacitance

3.999 μF

39.99 μF
399.9 μF

3999 μF

± (1.9% + 8dgt)

Overload protection : 1000 V

rms

This manual is related to the following products: