beautypg.com

Electrical specifications – Seaward Power Clamp User Manual

Page 25

background image

24

Electrical Specifications

Accuracy is ±(% reading + number of digits) at 23°C ± 5°C
< 80%RH.


(

1) Voltage

Function

Range

Accuracy*

DCV

99.99V

± (0.7% + 2dgt)

999.9V

ACV

99.99V

± (1.0% + 5dgt)

50 ~ 500Hz

999.9V

LPF

ACV

99.99V

50 ~ 60Hz ± (1% + 5dgt)

>60 ~ 400Hz ± (5% + 5dgt)

999.9V

* DCV <1000dgt, add 6 dgt to the accuracy.
ACV <1000dgt, add 3 dgt to the accuracy.
Overload protection : 1000V

rms

Input Impedance : 3.5MΩ // <100pF
AC Conversion Type : AC Conversions are ac-coupled, true
RMS responding, calibrated to the RMS value of a sine wave
input. Accuracies are given for sine wave at full scale and non-
sine wave below half scale. For non-sine wave (50/60Hz) add
the following Crest Factor corrections:
For Crest Factor of 1.4 to 2.0, add 1.0% to accuracy.
For Crest Factor of 2.0 to 2.5, add 2.5% to accuracy.
For Crest Factor of 2.5 to 3.0, add 4.0% to accuracy.
CF 3 @ 460V, 280A
2 @ 690V, 420A

AC+DC Vrms Accuracy : same as ACV spec. +DCV spec.