beautypg.com

Seaward KD1E User Manual

Page 13

background image

KD1E Range

Operating Instructions

11

7.0 Battery

Charging

This section is a requirement for digital reading potential
indicators only.

A “BAT” sign on the display of the digital
potential indicator denotes that the battery
requires charging.

During prolonged storage periods the battery will
discharge. In order to increase the battery life
the instrument should be charged periodically.

7.1

Remove the protective cap from the connector on

the bottom of the hand held section of the indicator.

7.2

Insert the 6 pin socket fl

ying lead from the

PSU100 battery charger – Seaward Part 124A912

into the connector and fi rmly screw into place.

Connect the mains lead from the charger to a

240VAC 50Hz supply and switch on.

7.3

Once mains has been applied to the battery

charger one LED is continuously illuminated and a

second LED will fl

ash approximately every 5

seconds to indicate the digital display battery is

being

charged.

7.4

The charging period should be approximately

14 hours. Once charging is complete both LED’s

are switched off.

7.5

On completion of the charging cycle, disconnect

the battery charger supply from mains, disconnect

the 6 pin socket from the base of the potential

indicator and replace the protective cap over

the

plug.

Do not use the potential indicator on a high
voltage circuit while the battery is on charge.