Test Procedure C

Earthed (Class I) Products plus Light-Up test


Light-Up Test

45. Fit appropriate lamps into the product, making sure not to exceed a maximum of 600W loading.

46. Ensure product switches are set to the ON position.

47. Ensure the TEST INHIBIT lamp is not on – if it is, check that the lamp loading is not excessive or disconnect

the product and check for any sources of short circuit in the wiring.


48. Depress the panel mounted SAFETY button and hold it in, then turn the Light-Up Test keyswitch to the ON

position and hold it there. The lamps in the product should light. If not, suspect a faulty lamp. Release the
keyswitch and SAFETY button.


WARNING

ONLY APPLY THE LIGHT-UP TEST ONCE – do not keep flicking the switch on and off as this may cause
nuisance tripping of the supply RCB.