Connect the water supply

Plumbing information:
• The water supply connection is at the back panel. It

is a 5’ (1.5 meter) 1/4 inch (6.35 mm) OD plastic tube.

• A hand actuated valve within site of the machine is

required to isolate the unit when it’s being serviced.

• The machine has a built-in back flow preventer (an

air gap between the end of the water inlet hose and

the top of the reservoir water), no additional back flow

preventer is needed.

• Water flow rate into machine is .25 GPM / .94 LPM.

Units that are built into a cabinet:

Include a loop or coil of tubing between the water

supply and the connection on the ice machine. When

the machine is pushed back into the cabinet the

tubing will coil and not kink.

Connection Information:

WARNING: connect to potable water supply only.

Important: Open the hand water valve to flush

water through the connection point before

connecting to the ice machine.
1. Cut cable ties securing hose and power cord to

unit.

2. Connect to cold, potable water using the

necessary adapters for the 1/4 inch OD plastic

tube.

• If using compression fittings they require a ferrule or

sleeve and insert.

• A female 3/8 compression adapter x 1/4 OD

compression allows connection to a typical 3/8 OD

compression angle valve.

• Another connection method is by quick connect

fittings.

Note: Do not use a piercing-type saddle valve to

connect to the building’s water supply. Valves of

that type restrict water flow and clog easily.
Connect the drain
The drain connection is at the back panel. The fitting

size is ¾ FPT.

1. Connect rigid tubing to this fitting and vent it at the

machine, use an 8 inch or 200 mm vertical tube

for the vent.

2. Slope drain tubing down from the ice machine to

the building drain and the slope must be at least ¼

inch per foot or 20 mm per meter.

3. Insulate the drain tubing to reduce condensation

and is recommended for environments that have

high humidity.

Due to the potential for leaks, condensate pumps are

not recommended.

Drain Fitting, 3/4 FPT

Potable Water Inlet Tube