Service Manual for Models CU0415, CU0715 and CU0920

August 2013

Page 20

Controller Self Test
Control Board Self-Test Routine. Begin with unit

unplugged and no ice touching the bin control.

1. Remove top and back panels to access thermistor

on suction line (above accumulator).

2. Remove the thermistor probe from the suction

line.

3. Shut water supply off.

4. Remove front panel to access control.

5. Place evaporator thermistor probe in ice water, ice

water temperature should be 0 C or 32 F.

6. Plug unit in, master switch in the ON position.

5 minutes or more after the freeze cycle starts

check reservoir water temperature. When it and

the evaporator thermistor’s ice water are at 32 F,

hold BOTH upper left - button and lower right +

button in for at least 5 seconds, then release the

buttons.

7. The green level LEDs will turn off and the yellow

Timer LED will turn on for two seconds once you

have entered the test mode.

8. Press upper left - button and the evaporator

thermistor temperature test will begin. The

yellow Timer LED will turn on for 2 seconds if the

evaporator thermistor temperature is 32 F +/- 2

degrees.

9. Press upper left - again and the sump thermistor

temperature test will begin. The yellow Timer LED

will turn on for 2 seconds if the sump thermistor

temperature is 32 F +/- 2 degrees. Note:

Pressing - repeatedly will toggle between testing

the two thermistor temperatures.

10. Press upper right + button and the Freeze relay

will close and the blue Freeze LED will turn on for

5 seconds. Compressor, fan motor and pump will

start. If not, the controller has failed.

11. Press upper right + again and the Pump relay will

switch, the pump will stop and red LED (on back

side of the board) will turn on for 5 seconds. Note:

Pressing + repeatedly will toggle between testing

the two relays.

12. Press and hold lower left - button and it will turn

on each of the green LEDs, one at a time. Hold

lower left – button in until all of the green LEDs

are tested.

13. Press lower right + button to test the EEPROM

read and write. The yellow Timer LED will turn

on for 2 seconds if the EEPROM read and write

operations were successful.

Power down the board to exit the test mode.
Test Results:

Step

Pass

Fail

Action if Failed

8

Yellow Timer LED

switches ON

No timer

light

Replace

thermistor set

9

Yellow Timer LED

switches ON

No timer

light

Replace

thermistor set

10

Compressor, fan

motor and pump

start

Either

compressor

or pump do

not start

Check voltage

to compressor

or pump, If

no voltage

to one or

both, replace

controller.

11

Water pump

stops

Pump does

not stop

Replace

controller

12

All green LEDs

light up

Some do not

illuminate

Replace

controller

13

Yellow Timer LED

switches ON

No timer

light

Replace

controller

If the controller passes all tests, there is nothing

wrong with it and the issue is in something else.

1. Reattach evaporator thermistor to the suction line

at the same place it was mounted and re-insulate

it.

2. Reconnect water supply, restart unit and return all

panels to their original positions.

September 2014