Service Manual for Models CU0415, CU0715 and CU0920
Components

Compressors, three capacities
Type: Hermetic

Brand: Embraco

Condenser: air cooled forced draft, copper and

aluminum.

Evaporator: Nickel plated copper, inverted grid
Ice: Medium / Full Dice cube. 5 x 9 per cycle, about 1

lb per cycle

Metering device: Capillary tube
Refrigerant: R-134a.
Refrigerant Charge: 8 ounces, all models. No access

valves.

Fan motor: Unit motor, CU0415 and CU0715 are 2.3

watts; CU0920 is 6 watt. Fan motor may cycle during

freeze, should be off during harvest as the discharge

pressure will be below 100 PSIG.

Fan blade: Molded
Fan pressure control switch: Opens at 100 PSIG,

closes at 150 PSIG.

Water pump: OEM
Hot gas valve: Ported, line voltage coil
Inlet water solenoid valve: .275 GPM flow, line

voltage coil

Transformer: Output 12 volt AC
Controller: Microprocessor operated relays for fan

and pump. Internal electronic timer. Bridge thickness

and harvest time adjustable on controller. Indicator

lights for bridge thickness and harvest time. No

maximum or minimum time limits or error codes.

Lights for timer, freeze mode and anti-slush mode.

Thermistor failure indicated by all Bridge Thickness

and Harvest Time green lights blinking. Unit continues

to operate on a fixed timed freeze and harvest cycle.

Sensors: Thermistor for suction line temperature,

Thermistor for reservoir water temperature.

Bin Thermostat: Opens on temperature fall, must be

closed to power control system. Operates compressor

directly.

Master switch. On, Off, or Wash. DPDT, not a service

disconnect.

On: When contacts 2-1 are closed power is connected

to the bin thermostat, allowing it to automatically

switch the machine on and off.

At the same time contacts 5-4 are closed, making a

circuit to the pump common and fan motor pressure

control.

Off: all contacts open.

Wash: Contacts 2-3 provide a connection to contacts

5-6, connecting power to the pump common. Only

the pump operates when the switch is in the Wash

position.

Evaporator

Thermistor

Mounted above

accumulator,

clipped to suction

line.