Performance – Scotsman CU0415 User Manual
Page 17
Service Manual for Models CU0415, CU0715 and CU0920
August 2013
Page 16
Performance
CU0415
Compressor amp draw, 115 volt
• Freeze, 5 minutes in: 1.8 to 1.9
• Overall Freeze cycle amps, begin at 1.9 decline to 1.7.
• Harvest: 1.9 - 1.8
Compressor dome is normally warm.
Drain water per cycle at standard harvest setting: about 1.4 quarts, at shorter setting drain water reduced to 1
quart.*
CU0715
Compressor amp draw, 115 volt
• Freeze, 5 minutes in: 2.6
• Overall Freeze cycle amps, begin at 2.7 decline to 2.5
• Harvest: 2.9 - 3.2
Drain water per cycle at standard harvest setting: about 1 quart, at shorter setting drain water reduced slightly.*
CU0920
Compressor amp draw, 115 volt
• Freeze, 5 minutes in: 3.1
• Overall Freeze cycle amps, begin at 3.5 decline to 2.9
• Harvest: 3.3 - 3.7
Drain water per cycle at standard harvest setting: about 2 quarts, at shorter setting drain water reduced to 1.7
quarts.*
* Drain water is directly affected by harvest time, these numbers will vary with air and water temperature
changes.