beautypg.com

Cme2006r, Bin control: installation – Scotsman CME2006R User Manual

Page 6

background image

Bin Control: Installation

The bin control is a thermostat. It must be field
installed after the ice machine has been placed on
the bin.

Before starting, remove the left front panel and
any baffle in the bin.

1. Locate bin thermostat bulb.

2. Route bulb thru routing tube (located between
the compressor and the reservoir).

3. Locate bin thermostat bracket.

4. Carefully position the thermostat bulb on the
bracket (see the diagram on the next page).

5. Fasten the bracket to the bottom of the ice
machine with the two 3-pronged knobs supplied
with the unit.

6. Pull back into the ice machine any excess
capillary tubing.

7. Return the baffle to the bin and continue with
the installation.

Note: If the machine is located at an altitude
higher than 2,000 ft., adjust the thermostat by
removing the plastic cover and rotating the
adjustment screw per the table.

Bin Thermostat Bulb

Route Bin Thermostat Bulb Into Bin

Bin

Thermostat

Body

Thermostat Bulb

Routing Tube

Bin Thermostat Altitude Correction Table

CW Turns of Range Screw (under plastic cover)

Feet

Turns

Feet

Turns

2000

55

o

8000

340

o

4000

160

o

9000

385

o

6000

250

o

10000

405

o

Use This Table to Adjust Thermostat