How The Electronic Cuber Works
This section is intended for the technician. It is not necessary for the normal operation and maintenance
of the machine.
SureFlow
™
Remote System:
Freeze Cycle: Heat is removed from the water and
discharged out the condenser during the freeze
cycle. As liquid refrigerant passes thru the
Thermostatic Expansion Valve, it enters the top of
the evaporators, and ice will form at the top first.
When cubes need to be released (Harvest) the Hot
Gas Valve is opened and Hot discharge gas flows
directly from the compressor to the evaporator
inlets. At the same time, a Harvest Bypass Valve
opens for a few seconds to add the refrigerant
needed for harvest. After that the Harvest Bypass
Valve and the closed Discharge Check Valve
keeps the refrigerant in the condenser out of the
Hot Gas Circuit.
This warms up the evaporators and the surface of
the ice frozen to the evaporator surface melts. Ice
then falls into the bin.
The Check Valves also prevent liquid migration
during the Off cycle.
Receiver
Thermostatic
Expansion
Valve
Evaporator
Evaporator
Evaporator
Compressor
Remote Condenser
Refrigerant
Distributor
Hot Gas
Valve
Check
Valve
Check
Valve
Suction
Discharge Line
Accumulator
Head
Pressure
Control
Valve
Harvest
Bypass
Valve
Heat
Exchange
Refrigeration Schematic
CME2006R
July 1998