background image

Removal and Replacement

Purge Valve

1. Disconnect electrical power.

2.

Remove left front panel.

3. Unplug wire harness from purge valve coil.

4. Locate and remove the two screws securing the
purge valve to the machine.

5. Pull the inlet and outlet hoses off the purge
valve and remove it from the machine.

6. Reverse to reassemble. There are no internal
parts available for this valve.

Water Level Sensor/Float Stem

Note: Only one float stem fits this product. Be
SURE that this is the correct one.

1. Disconnect the electrical power.

2. Remove the front panel.

3. Remove 1 plastic bolt and the reservoir cover.

4. Pull float ball from float stem (it is a snap fit). Pull
stem out.

5. Locate water level sensor mounting tabs,
compress together to release sensor from bracket.

6. Remove harness from sensor.

7. Reverse to replace.

8. Replace front panel.

9. Re-connect electrical power.

Water Level Sensor

1. Remove front panel.

2. Push and hold the OFF button. Release it when
the machine stops.

3. Trace wire harness from water level sensor to
the System Controller (#2). Unplug the harness
from the controller.

4. Lift the pump and mounting plate up enough to
remove the float from the stem.

5. Remove two screws holding the sensor to the
pump bracket and lift the sensor up and out of the
machine.

6. Reverse to reassemble.

Electrical Shock Hazard.

Disconnect electrical
power before beginning
service.

CME2006R

July 1998

Page 38