Service Diagnosis: Diagnostic Light Analysis

Problem or Symptom

Possible Cause

Probable Correction

Machine is off

Bin is full

Use some ice

Bin thermostat is closed

Check thermostat, unplug the connection to
the controller at terminal 7 and wait 4
minutes. If the machine starts, the thermostat
was closed and needs to be adjusted or
replaced. If the Bin Full light does NOT go out
check the ice sensors. See next page bottom.

Power is off, check Lights.

If all Lights are out, check power supply,
restore power if off

Transformer is open

If all Lights are out and there is power, check
transformer output for 24 vac

Unit manually switched off

Push and release Freeze button

Unit has Shut Down

Check for Refrigeration or Water Error

Unit is off on a Water
Error

Water supply inadequate

Check water Light, if the Light blinks 2 times
and repeats, check the water inlet valve.**

Water pump malfunction

Check that pump hose is attached and if
pump is plugged in and working.

Water level sensor may
have failed.

Check float stem, reset machine. If it will not
reset or gives another water error and all else
is OK, replace the water level sensor.

Unit is off on a
Refrigeration Error

Low discharge or long
freeze cycle

Check refrigeration Light. If the Light is
glowing, there is a probable refrigeration
problem - Check fan motor, harvest bypass
valve and/or controller.

Harvest problem

Check refrigeration Light. If the Light blinks
once and repeats, look for a harvest problem.
where some cubes were sensed.**

Check refrigeration Light. If the Light blinks
two times and repeats, look for a harvest
problem. - no cubes sensed**

High Discharge Temp

Check refrigeration Light. If the Light blinks 3
times and then repeats, check for a reason
for high discharge temperatures - fan motor
hot ambient, or blocked headmaster.

Unit does not go into
harvest - exceeds
maximum freeze time

Push and release Off button. Push and
release Freeze button. Check operation.

Push cube size float down, check operation.

Exceeds max harvest time

Check for cause of long harvest cycle**

Unit runs and both
Diagnostic lites are ON

Temperature sensors out
of range

Replace the temperature sensor set (water
and discharge).

Same, only 1 light on

Reservoir temp. wrong

Check water temp. and sensor.

* Machine may be reset by pushing and releasing the Off button, then pushing and releasing the
Freeze button. ** See following pages