Service Diagnosis: Components

Problem or Symptom

Possible Cause

Probable Correction

Fan motor does not
turn.

Open motor windings, or
seized bearings

Replace fan motor

No power to fan motor

Contactor may not close.

Pump motor does not
turn

Open motor windings, or
seized bearings

Replace pump

No power to pump

Check electrical connections. In Freeze, the
pump should have power to it. If not, replace
the System Controller.

Hot Gas Valve does
not open.

Open solenoid coil.

Replace hot gas valve

Stuck valve

Replace hot gas valve

No power to coil in Harvest

Check wire connections, if ok, replace
System Controller

Hot Gas Valve leaks
thru (warm tube
temperatures on both
sides of valve during
freeze)

Mechanical problem in
valve

Replace valve

Water Inlet Valve
does not open

Open solenoid coil

Replace valve

Stuck valve

Replace valve

No power to valve (best
checked at the beginning
of Freeze)

Check wire connections, if ok, replace
System Controller

Water Inlet Valve
does not flow enough
water

Restriction in water supply

Check water filters and/or inlet screen.

Water Inlet Valve
leaks thru

Mechanical problem in
valve

Replace valve

Compressor runs, but
loudly & no ice is
made

Three phase compressor
is phased wrong

Switch any two wires to the compressor

Compressor does not
work

Unit in Clean cycle

Push and release Freeze button.

Contactor coil open

Replace contactor

Open starting components

Check and replace

Open windings

Check and replace compressor

Internal valve failure

Replace compressor