How To Operate The System Controller
The System Controller is a
microprocessor based device that
receives input from several sources
and switches various components
on and off.
Its manual control is thru the use of
the Push Button Control Switches
1. Freeze Button. Pushing and
releasing this button starts or
restarts the machine. The System
Controller remembers what cycle it
was last in and returns to that cycle.
2. Harvest Button: Pushing and
releasing this button will cause the
machine to go directly to a Harvest
Cycle. Can be done from Freeze or
Off. The machine will switch Off at
the end of the Harvest cycle.
3. Clean Button: Pushing and
releasing this button will cause the
machine to empty the reservoir, refill
and leave only the water pump on
for circulation of ice machine
cleaner. After the ice machine
cleaner has circulated for about 10
minutes a second push of this
button will switch on the rinsing
system to flush out the dissolved
scale and ice machine cleaner.
4. Off Button: Pushing and
releasing this button will switch the
machine OFF at the end of the next
cycle. If the button is pushed and
HELD for more than 3 seconds, the
unit will switch off immediately.
To Reset Errors: First push and
release the Off button, then push
and release the Freeze button.