Service Diagnosis

Problem or Symptom

Possible Cause

Probable Correction

Unit is off because of
a “Harvest Problem”

Bin controls did not sense
ice falling, unit stayed in
harvest until the maximum
harvest time ran out.

Check bin controls. If the bin full light is on or
blinking the bin controls may be dirty. Clean if
dirty. The board and bin controls may also
need to be checked.

Check evaporators for lime scale build up.
Clean evaporators and bin controls if dirty.

Push and release Off button. Push and
release Freeze button. Check machine
operation. Check if ice is made and harvests.

Bin controls or System
Controller may have failed.

See “Unit does not shut off” below..

Other components may
have failed

Check the next page

Cubes are too large

Water sensor float is
sticking.

Check/clean

Inlet water valve leaking
thru (slowly)

Check hose from water valve for slow drip.
Replace valve if dripping.

Cubes are too small

Not enough water

Check for leak in reservoir

Check/clean water sensor eyes

Check for a leak thru the purge valve

Low ice capacity

Dirty condenser

Clean condenser

Recirculation of air

Block air re-circulation or move condenser

Low refrigerant charge

Check system. If there is a low charge, find
the leak, recover the refrigerant, repair the
leak, replace the dryer, evacuate and weigh
in the nameplate charge.

Too much water

Check for inlet water valve leak thru

Unit does not shut off

Ice sensing system may
have failed.

Check controls. Unplug thermostat and check
bin full light, if off, place something between
the electric eyes. The bin full light should
begin to blink (after 20 seconds of continuous
blockage it will glow steadily). If not, check
operation of electric eyes by unplugging #4
and jumping out the two pins on the controller
(touch the tool to the cabinet to discharge
static electricity before contacting the
controller). If the bin full light blinks, replace
the bin controls. If it does not blink, replace
the controller. Note: Leaving #4 unplugged
and jumped for 20 seconds will shut the
machine down on a bin full (at the end of the
harvest cycle). It will restart after 4 minutes or
may be reset by pushing the Freeze button.