C0322 through C1030
Air and Water Cooled User Manual
November 2012
Page 4
Product Description & Electrical Requirements
Dimensions w" x d" x h" Model
Series
Electrical
volts/Hz/
phase
Condenser Minimum
Circuit
Ampacity
Maximum
Fuse Size*
22.75** x 24 x 23
C0322SA-1
A or B
115/60/1
Air
12.7
15
C0322SW-1
A or B
115/60/1
Water
11.9
15
C0322SA-32
A or B
208-230/60/1 Air
6.1
15
C0322SW-32
A or B
208-320/60/1 Water
5.6
15
C0522SA-1
A or B
115/60/1
Air
13.8
15
C0522SW-1
A or B
115/60/1
Water
12.2
15
C0522SA-32
A or B
208-230/60/1 Air
7.6
15
C0522SW-32
A or B
208-230/60/1 Water
6.7
15
30.75** x 24 x 23
C0330SA-1
A or B or C
115/60/1
Air
12.7
15
C0330SW-1
A or B or C
115/60/1
Water
11.9
15
C0330MA-32
A or B or C
208-230/60/1 Air
6.1
15
C0330SW-32
A or B
208-230/60/1 Water
5.6
15
C0530SA-1
A or B
115/60/1
Air
13.9
15
C0530SW-1
A or B
115/60/1
Water
12.2
15
C0530SA-32
A or B
208-230/60/1 Air
7.9
15
C0530SW-32
A or B
208-230/60/1 Water
6.7
15
C0530SA-1
C
115/60/1
Air
15.2
20
C0530SW-1
C
115/60/1
Water
13.5
15
C0530SA-32
C
208-230/60/1 Air
7.8
15
C0530SW-32
C
208-230/60/1 Water
6.6
15
C0630SA-32
A or B
208-230/60/1 Air
18.2
20
C0630SW-32
A or B
208-230/60/1 Water
17
20
22.75** x 24 x 29
C0722SA-32
B
208-230/60/1 Air
10
15
30.75** x 24 x 29
C0830SA-32
A or B
208-230/60/1 Air
10.2
15
C0830SW-32
A or B
208-230/60/1 Water
9
15
C0830SA-3
A or B
208-230/60/3 Air
8.4
15
C0830SW-3
A or B
208-230/60/3 Water
7.2
15
C1030SA-32
A or B
208-230/60/1 Air
16
20
C1030SW-32
A or B
208-230/60/1 Water
14.8
15
C1030SA-3
A or B
208-230/60/3 Air
11
15
C1030SW-3
A or B
208-230/60/1 Water
9.8
15
Table notes: Medium cube models have the same electrical characteristics as Small. Series revision code
omitted.
* Or HACR type circuit breakers.
** Maximum width at top panel. Air cooled models add .75" for left side louvers.