C0322 through C1030

Air and Water Cooled User Manual

November 2012

Page 11

Electrical

The machine is not supplied with a power cord as the

machine is designed to be permanently connected.

The dataplate on the back of the cabinet details

the power requirements, including voltage, phase,

minimum circuit ampacity and maximum fuse size.

HACR type circuit breakers may be used in place of

fuses. Extension cords are not permitted. Use of a

licensed electrician is recommended.

Electrical connections are made inside the junction

box in the back panel of the ice machine.

1. Remove the junction box cover and route the

electrical supply cable through the access hole

and properly attach the power supply wires to the

leads in the junction box.

2. Install a field supplied strain relief per code. Attach

a ground wire to the ground connection in the

junction box.

3. Check voltage when complete.

4. Return the junction box cover to its original

position and secure with the original screws.

The electrical disconnect switch with fuse protection

must be a two pole type with a minimum of 3 mm

between open contacts.

Follow all applicable local, state and national codes.