RC4000 Antenna Controller
Chapter 3
Software
90
3.3.1.3.5 Elevation Pot Drive
CONFIG-EL POT
FAST/SLOW: 0.5 COAST: 0.3
MAX ERROR: 0.01 TRIES: 3
SET THRESHOLD <0.0-10.0 DEGREES>
The CONFIG_EL POT screen contains configuration items for calibrating elevation movements based on
potentiometer position feedback. See the Drive System theory section 1.3.7.
FAST/SLOW:
SET THRESHOLD <0.0-10.0 DEGREES>
During an automatic move, the elev_fast_slow_threshold configuration item is used to set the number of
degrees before a target position is reached, when the controller switches the speed of the drive from fast
to slow.
MAX ERROR:
SET MAXIMUM ERROR <0.01 - 1.00 DEGREES>
The elev_max_position_error configuration item sets the maximum acceptable error between the final
resting position and a target position during an automatic move.
COAST:
SET COAST RANGE <0.0 - 2.0 DEGREES>
During an automatic move, the elev_coast_threshold configuration item sets the number of degrees
before the target position is reached where the drive will be deactivated. The idea is to deactivate the
drive and let the antenna coast into position. If prior to the initiation of the move operation, the total
number of degrees that the actuator has to move to reach the target position is less than the 'Coast
Threshold, the drive will be deactivated when its position is within 'Max Position Error of the target
position.
RETRY:
SET MAX NUMBER OF TRIES <0-10>
The elev_auto_move_max_retry_cnt configuration item sets the maximum number of attempts which will
be made to hit a target position (within Max Error - described above) during an automatic move based
on potentiometer feedback.