13 reset system data – Research Concepts RC2000C User Manual
Page 69

RC2000C Az/El Tracking Antenna Controller
Chapter 5
Modes Function Description
61
Research Concepts, Inc. • 5420 Martindale Road • Shawnee, Kansas • 66218-9680 • USA
www.researchconcepts.com
The purpose of this feature is to keep an operator away from the modes and CONFIG mode items that
can change the contents of the controller's non-volatile memory.
When the Expert Access screen is displayed, the present state of the Expert Access Flag is displayed in
the data entry field. A display value of 1 indicates that the Expert Access Flag is set, and a value of 0
indicates that the flag is reset. To toggle the state of the flag, the user must key in a 5 digit code at the
prompt followed by the ENTER key. This code is found in a removable Appendix at the end of this
manual. If the information is lost, call the factory for assistance.
EXPERT ACCESS (0-OFF, 1-ON): 1 CONFIG
ENTER CODE TO TOGGLE ENT,BKSP,SCRLL ^v
5.10.13 Reset System Data
The Reset System Data CONFIG mode data item is used to reset the controller's non-volatile memory.
When this occurs, the azimuth and elevation limits are invalidated, and most of the various CONFIG
mode items are initialized to a default value. This operation is usually performed at the factory. Access
to this item is allowed only when the Expert Access flag is set. To reset the system memory, the user
must key in the same 5 digit code used for Expert Access, followed by the ENTER key.
RESET SYSTEM DATA: 0 CONFIG
ENTER CODE ENT,BKSP,SCRLL ^v
Following are the default values that are assigned to non-volatile memory on system reset. A space is
provided to record the values of the CONFIG mode items that are assigned by the user.
CONFIG Mode Item
Default Value
Record Actual
Value
Azimuth Position Count:
5000
Azimuth CCW Limit:
4999
_________________
Azimuth CW Limit:
5001
_________________
Azimuth Limit Checksum:
Invalid
Elevation Position Count:
5000
Elevation Down Limit:
4999
_________________
Elevation Up Limit:
5001
_________________
Elevation Limit Checksum:
Invalid
AutoPol Enable:
0
_________________
AutoPol Vpol Level:
1 (Vertical)
_________________
Simultaneous Az/El Enable:
0 (Disabled)
_________________
Remote Mode Enable:
0 (Disabled)
_________________
Comm Port Address:
50
_________________
Comm Baud Rate:
9600
_________________
Azim Slow Speed:
253 (Disabled)
_________________
Elev Slow Speed:
253 (Disabled)
_________________