Various values are summarised here in order toe enable quick access for customer service.
The input of the code number is necessary for some functions.
The relay test and sensor test are automatically reset after 1 minute!

Sensor test no.
Sensor no.

REMKO
Sensor
designa-
tion

Terminal
layout in the
indoor unit

Description

01

Buffer tank temperature bottom

02

Buffer tank temperature middle (or room temperature Heating circuit 1)

03

Buffer tank temperature top

04

not used

05

F5

X3.16

Supply temperature heating circuit 2 (mixer circuit)

06

F6

X3.15

Hot water temperature top (process water tank)

07

not used

08

F8

X3.14

Collector temperature (collective supply temperature sensor)

09

F9

X3.13

Outdoor temperature

10

not used

11

F11

X3.12

For CMF 80/90/140/150 and CMT 100/150:

Supply temperature heating circuit 1 (direct heating circuit) or

for CMF/CMT 120 and CMF/CMT 160:

Supply temperature heat pump

12

F12

X3.11

Hot water temperature bottom (reference sensor for solar regulation)

13

F13

X3.10

not yet used (solid material WE temperature (PT1000))

14

F14

X3.9

Collector temperature solar system (special control characteristic
(PT 1000))

15

F15

X3.8

Flow meter

16

not used

17

F17

X3.7

Return temperature sensor

Level 4 - SERVICE - Description of parameters and settings

21