REMKO Heat Pump Manager
Level 4 - DISPLAY - Description of parameters and settings
DISPLAY
Hot water
End
01
T-WW
T-WW U
WW demand
WW pump
WW enable
Circulation pump
Heating circuit 2
End
01
T-room
T-supply
Heating circuit enable
Heating circuit pump
B-warm up-time
Heating circuit 1
End
01
T-room
T-supply
Heating circuit enable
Heating circuit pump
B-warm up-time
Solar / MF
End
01
MF 1
MF 2
T-MF 3
MF 3
MF 4
T-solar 1
T-WW
T-WW U
Solar pump 1
Load Sp WW
Display of system values
Values cannot be changed in the display section.
There is a display only if the respective sensor is connected or the value exists in the system. If the setting does
not exist, it is either hidden or dashes (----) are shown in the display.
Factory settings can vary depending on the system.
Plant
Designation
Description
T-external
Current outdoor temperature [sensor 09] (smoothed value).
T-collector
Current collector temperature [sensor 8] and (collector) target temperature Display following pressing of
the respective function key.
The target corresponds with the highest temperature demanded in the load circuits (incl. water heating).
T-WE
Current temperature of all connected heating appliances [sensor 08].
WE status
Heating appliance's status (on / off).
T-return total
Current return temperature for the start of the cooling machines (see specialist
cooling mode
T-RL cooling) and for the shut-off of the heat pumps (see specialist
heat pump
Max T-return WP, return offset) [sensor 17].
T-tank 3
Current temperature of the tank 3/buffer tank bottom [sensor 01]. No assignment by REMKO
Modgrad
Current target modulation depths for all active WE and required modulation depth.
Volumetric flow
Display of the current flow volume (flow) in l/min
Output current
Display of the current heating/cooling output in W
Output day
Display of the amount of heat delivered in kWh during the previous day. The value updates itself auto-
matically at 0:00 (midnight)
Output total
Display of the amount of heat delivered since commissioning (cumulative). The meter reading is updated
every day at 0:00 (midnight) by the amount of the day's output.
Error
Error number (00 = no errors).
01
Plant
End
T-external
T-collector
T-WE
WE status
T-return total
T-tank 3
Modgrad
Volumetric flow
Output current
Output day
Output total
Error
12