Remko pww, Safety information, Unit description – REMKO PWW Series User Manual

Page 4

background image

4

REMKO PWW

Safety information

The units were subjected to ex-
tensive material, functional and
quality inspections and tests prior
to delivery.

The units can however constitute
a hazard if used improperly by
untrained persons or not for the
intended purpose.

Always observe the following
safety information:

The locally applicable building

regulations must be observed.

The operator is responsible for

correct installation of the units,
correct electrical installation and
safe operation of the units.

The units must be installed

and operated in a manner that
excludes any risk to persons
through radiated heat.

The units must only be attached

to constructions or ceilings with
sufficient load bearing capacity.

Attachment must take place

using suitable anchors to be at-
tached to the unit.

Only trained specialists may

install and connect the heating
medium, establish electrical con-
nections and carry out mainte-
nance.

The units must not be installed

and operated in locations
where there is a risk of fire and
explosion.

The units must be installed

outside traffic zones, e.g. also
the operating areas of cranes. A
protection zone of 1 m distance
must be kept free.

The units must only be operated

in a completely installed
condition.

Safety components, e.g. protec-

tion grilles must not be removed
or rendered inoperational.

The units must only be operated

within the specified capacity
limits and with the approved
operating media.
Observe rating plate!

The air intake grilles must

always be kept free of dirt and
loose objects and the air outlet
must not be closed.

Never insert foreign objects into

the unit.

The units must not be sprayed

with a direct jet of water.

Never allow water to enter the

unit.

All electrical cables of the units

must be protected against dam-
age, e.g. animals, etc.

Unit description

These units are stationary, indi-
rectly fed air heaters with copper/
aluminium fin heat exchanger for
connection to a pumped hot water
system up to max. 130°C.

The units are suitable for wall or
ceiling mounting.

The units can be provided with
diverse air inlet and air outlet
accessories.

The units are provided with hori-
zontal, individually adjustable air
outlet fins as standard.

The units are provided with a low-
noise, aerodynamically designed,
sickle-shaped high-power axial
fan, individually adjustable air out-
let fins and electrical terminal box.

The units are fitted with a
400V/50Hz, two-speed external-
rotor motor as standard.

The units comply with the basic
health and safety requirements of
the pertinent EU regulations and
are easy to operate.

NOtE

Perfect functioning of the units
is only ensured when the flow
temperature at the unit inlet
and the pump capacity cor-
respond to the selected unit
classification.