Remko pww, Safety information, Unit description – REMKO PWW Series User Manual
Page 4

4
REMKO PWW
Safety information
The units were subjected to ex-
tensive material, functional and
quality inspections and tests prior
to delivery.
The units can however constitute
a hazard if used improperly by
untrained persons or not for the
intended purpose.
Always observe the following
safety information:
■
The locally applicable building
regulations must be observed.
■
The operator is responsible for
correct installation of the units,
correct electrical installation and
safe operation of the units.
■
The units must be installed
and operated in a manner that
excludes any risk to persons
through radiated heat.
■
The units must only be attached
to constructions or ceilings with
sufficient load bearing capacity.
■
Attachment must take place
using suitable anchors to be at-
tached to the unit.
■
Only trained specialists may
install and connect the heating
medium, establish electrical con-
nections and carry out mainte-
nance.
■
The units must not be installed
and operated in locations
where there is a risk of fire and
explosion.
■
The units must be installed
outside traffic zones, e.g. also
the operating areas of cranes. A
protection zone of 1 m distance
must be kept free.
■
The units must only be operated
in a completely installed
condition.
■
Safety components, e.g. protec-
tion grilles must not be removed
or rendered inoperational.
■
The units must only be operated
within the specified capacity
limits and with the approved
operating media.
Observe rating plate!
■
The air intake grilles must
always be kept free of dirt and
loose objects and the air outlet
must not be closed.
■
Never insert foreign objects into
the unit.
■
The units must not be sprayed
with a direct jet of water.
■
Never allow water to enter the
unit.
■
All electrical cables of the units
must be protected against dam-
age, e.g. animals, etc.
Unit description
These units are stationary, indi-
rectly fed air heaters with copper/
aluminium fin heat exchanger for
connection to a pumped hot water
system up to max. 130°C.
The units are suitable for wall or
ceiling mounting.
The units can be provided with
diverse air inlet and air outlet
accessories.
The units are provided with hori-
zontal, individually adjustable air
outlet fins as standard.
The units are provided with a low-
noise, aerodynamically designed,
sickle-shaped high-power axial
fan, individually adjustable air out-
let fins and electrical terminal box.
The units are fitted with a
400V/50Hz, two-speed external-
rotor motor as standard.
The units comply with the basic
health and safety requirements of
the pertinent EU regulations and
are easy to operate.
NOtE
Perfect functioning of the units
is only ensured when the flow
temperature at the unit inlet
and the pump capacity cor-
respond to the selected unit
classification.