Before commissioning – REMKO CLK 80-RV User Manual
Page 9
9
Air distribution
The units are equipped with a high
performance radial fan, which
has been designed to transport
the heated air efficiently
and effectively over large
distances.
The distribution of the air
is preferably implemented via
ducting or special warm air
or membrane hoses.
■
Use hot air hoses approved
by us (accessories) exclusively
■
Observe the air flow direction
of the hoses with this!
The inner overlapping
on the seams of the hot
air hoses must point
in the direction of the air flow.
■
Make sure that the hose
or ducting is securely fastened
onto the unit outlet nozzle
and any connection pieces that
may be being used
■
Only suitable air distributors
or air distributors approved
by ourselves should be used for
the air distribution
■
Enclosed spaces being heated
via hoses must not present any
overpressure
■
The forced-air burner can
be switched off briefly during
operation by the temperature
monitor (TW) in the event
of there being increased intake
temperatures or resistance
at the unit's outlet.
After the temperature drops
again the burner starts anew
automatically!
■
If the cycle intervals are too
short the length and layout
of the hot air routing should
be checked
■
There should be no kinks
or bends in the layout of the
hoses in order to prevent hot-
spots forming.
Membrane hoses must not be
twisted
Suction air
Fresh air, mixed air or
circulated air operating modes
can be selected on the unit.
The following information refers
to the installation of the unit
outside the space to be heated.
Fresh air operation:
The air intake is implemented
in the factory through 2 intake
grills, right / left.
Mixed air operation:
For operation of the unit in mixed
air mode it is necessary to fit
the intake nozzles, available
as accessories.
In order to guarantee adequate air
throughput the second intake grill
must not be covered.
Circulated air operation
:
For operation of the unit
with 100% recirculated air
it is necessary to fit two intake
nozzles, available as accessories,
in place of the 2 factory-fitted
intake grills.
Before commissioning
The units should be checked for
visible defects on the operating
and safety devices as well
as proper installation and correct
electrical connections before
commissioning.
It is essential that the following
points be observed:
■
The units must be installed
in a stable position
■
Ensure there is sufficient supply
of combustion air
■
Check that the inlet and outlet
are free
■
Prevent overpressure
or underpressure
in the installation area
■
Ensure that there is sufficient
fuel supply and that it complies
with the respective local
regulations
■
Only use clean EL heating oil or
Diesel fuel. Do not use Bio-
Diesel!
■
The suction pipe in the base
of the tank must be fitted with
a foot valve as a matter of
principle
nOtE
After fulfilling the respective
local regulations as well
as a professional installation
of the unit, the exhaust values
for the forced-air burner must
be checked and adjusted
if necessary by authorised
specialists.
nOtE
The hot air hoses must only
be used in fully extended form
and without any constrictions.
nOtE
Air feeds on the intake side
must always be implemented
by means of non-distorting
hoses/ducts (no unstable
hoses).
AttEntiOn
If a build-up of heat should
occur then the heating
operation will be interrupted
by the STB permanently.
nOtE
Cycled operation
of the forced-air burner with
run times under 5 min. should
certainly be avoided.