beautypg.com

Commissioning the forced-air oil burner – REMKO CLK 80-RV User Manual

Page 20

background image

20

REMKO CLK 80/170-RV

After loosening the 4 fastening
bolts the mounting baseplate M
is pulled off the housing g.
From size SL 44, 6 fastening screws
must be removed (note marking
arrows).


The most important functional
parts for the installation /
maintenance are now immediately
accessible, as per the respective
requirements.

For maintenance work or for
installing / replacing the oil
nozzle, the mounting baseplate
M can be positioned on the
burner housing g in 2 ways (see
figs. 1 and 2).

The baseplate can be positioned
in the desired / possible position
on the special mounting points
in accordance with the unit-
specific options.

Commissioning the forced-air oil burner

Mounting baseplate

After having replaced the nozzle
and carried out any adjustments
required to the air inlet nozzle A,
the mounting baseplate M is re-
fitted in reverse order.

Adjusting the ignition electrode and baffle plate

All sizes are approximate values
and are in mm. The optimum
setting must be adapted to
the unit-specific and structural
conditions.

A

B

M

G

Fig.: 2

M

G

Fig.: 1

Size / dimensions A B C D
CLK 80-RV

5 5 7 3

CLK 170-RV

7 8 5 3

Required nozzle size

The selection of the required oil
nozzle is dependent on the pump
pressure and the unit capacity.
Only a nozzle that is approved
for the respective combustion
chamber geometry with
corresponding spray angle
and cone characteristics may
be used.
Refer to the technical data for
the required oil nozzle size.

Air inlet nozzle

The required blower pressure can
be adjusted with the adjustable air
inlet nozzle A in accordance with
the combustion chamber resistance
and chimney draft, without having
to change the output diameter.
1. Loosen the Allen screw B.
2. Turn the air inlet nozzle A

to the desired position (note
arrows!).

"min"

= Smaller blower pressure

"max"

= Larger blower pressure

Preparatory tasks

nOtE

Because the air flap, up to size
44, is sprung this should
be closed beforehand with
the help of the adjustment
screw [3] (turn adjusting screw
approx. as far as scale value 1).

AttEntiOn

The commissioning
of the forced-air oil burner
may only be carried out
by trained specialists.

This manual is related to the following products: