Control panel

1

2

9

8

7

6

5

1 = Thermostat receptacle
2 = Strapping plug
5 = Operating switch
6 = Indicator light "gREEN"
"Operation"
7 = Indicator light "RED"

"Burner fault"

8 = Reset button "Burner"
9 = Mains cable with plug

Heating without room
thermostat

The units are operating
in permanent operating mode.

1. Connect the strapping

plug supplied [2] with
the thermostat receptacle [1]
on the unit.

2. Move the operating

switch to the "I" (on)
position.

2

1

Commissioning

One person, who has been
adequately trained in the handling
of the unit, should be tasked with
the operation and monitoring
of the unit.

Connecting the units with
the electrical power supply

The electrical connection is made
using a built-in mains cable with
plug.

1. Move the operating

switch to the "0" (off)
position.

2.

Connect the power plug

with a properly installed and

appropriately safeguarded

mains socket

230V or shock-proof

400V/3~N/50Hz .

3. Open all of the oil supply shut-

off devices.
With the initial commissioning,
air in the lines can lead to
a fault shut-down of the
burner

.

s

s

s

Paraffin formation with low
outside temperatures

Even at low outside temperatures
it is necessary to ensure that there
is an adequate supply of heating
oil that is capable of flowing.

Paraffin formation can start

with temperatures as high
as 5 °C

To avoid this appropriate

preventative measures must
be implemented.
e.g. Winter-proof EL heating
oil or winter Diesel, heated oil
tank, insulated oil lines etc.

Note that fault-free operation

of the Multiflex oil pre-heating
can only be guaranteed
if the unit has been supplied
with electrical power for a long
period of time before starting

It is not possible to rectify

paraffin separation that
has already occurred with
the heating. If paraffin has
already formed it is necessary
to clean out the complete fuel
system

nOtE

The 400V version of the unit
is equipped with a device for
automatically checking the
turning direction of the fan
motor, as standard.

nOtE

The electrical connection
for the units must be made
at a separate feedpoint with
a residual current device
in accordance with VDE 0100,
Section 55.

AttEntiOn

All cable extensions must only
be used in fully un-reeled
or reeled off condition.

nOtE

Paraffin formation can start
with temperatures as high
as 5 °C. To avoid this
appropriate preventative
measures must be
implemented, e.g. winter
Diesel.