THERMAL CONSIDERATIONS


Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.

Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.

Thermal Testing Setup

Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics equipment.
This type of equipment commonly uses vertically mounted
circuit cards in cabinet racks in which the power modules
are mounted.

The following figure shows the wind tunnel
characterization setup. The power module is mounted on
a test PWB and is vertically positioned within the wind
tunnel. The height of this fan duct is constantly kept at
25.4mm (1’’).

Thermal Derating

Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power module
should always be operated below the maximum operating
temperature. If the temperature exceeds the maximum
module temperature, reliability of the unit may be affected.

DNT04S0A0R03(standard) Output Current vs. Ambient Temperature and Air Velocity

@Vin=5V Vout=0.75~3.3V (Through PCB Orientation)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

25

30

35

40

45

50

55

60

65

70

75

80

85

Natural

Convection

Output Current (A)

Ambient Temperature (℃)

Figure 33: Output current vs. ambient temperature and air
velocity @ Vin=5V, Vout=0.75V~3.3V(Through PCB Orientation)

THERMAL CURVES

Figure 32: Temperature measurement location
The allowed maximum hot spot temperature is defined at 125