beautypg.com

ONICON System-10 P1 User Manual

Page 49

background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 • [email protected]

System-10-P1 Manual 10/14 - 0656-9 / 18320

A - 7

STANDARD INSTALLATION DETAIL FOR

HEAVY DUTY THERMOWELL

In Welded Pipe

1500 North Belcher Road, Clearwater

, FL

33765 • T

el (727) 447-6140 • Fax (727) 442-5699

www

.onicon.com • [email protected]

1/2” coupling

1/2” extension

nipple

heavy-duty thermowell with 1/2” NPT

process

thread (length varies with

pipe size)

Step 1: Drill 7/8” hole in pipe. Install thermowell using fittings supplied by ONICON.

Complete steps 2-4 only after all welding, brazing & soldering are complete.

NOTE: Each sensor and transmitter are factory matched to each other and to a particular System-10 BTU Meter

.

connection

head

1/2” fitting

transmitter

retainer nut

(finger tighten only)

SS spacer sleeve (length varies with thermowell length)

platinum R

TD

Step 2: Remove lid and insert R

TD assembly into

thermowell, ensuring that it bottoms out.

Thermal compound may be used; apply only a pea-sized amount to the tip of the R

TD

prior to insertion.

Thread retaining nut onto fitting at bottom of connection head and hold sensor in place while tightening the nut by hand.

DO NOT OVER

TIGHTEN.

Step 3: Place the transmitter onto the exposed end of the SS spacer sleeve, gently guiding the excess wire through the center hole of the transmitter

.

Use caution to avoid pinching the wires or pulling the sensor out of the thermowell.

Step 4: Connect field wires from the System-10 BTU Meter to the transmitter as shown.

Carefully coil extra wire and thread the lid onto the connection head.

TRANSMITTER WIRING

REFERENCE

SIGNAL

TO BTU METER

TO

RT

D

HEA

VY DUTY THERMOWELLS FOR SYSTEM-10 BTU METERS

FOR PROCESS TEMPERA

TURES OVER 300

° F

0499-2

07-10