Installation, Wiring, Page 9 ht34-pv series power vent gas fireplace – Montigo HT34 PV User Manual
Page 9: Gas control and pilot wiring, Wiring for the optional fan kit
Page 9
HT34-PV Series Power Vent Gas Fireplace
Part No. XG0530 - 041510
Installation
Wiring
Gas Control and Pilot Wiring
HT34-PV-I
Figure 26.
Wiring for the HT34-PV-I with Honeywell gas control and pilot.
Wiring for the optional Fan Kit
All HT34-PV Series fireplaces may be equipped with optional fan kits
for circulating heat into the living space.
Installations in Canada which employ the fans must be electrically
grounded in accordance with CSA C22.1 Canadian Electrical Code
Part 1 and/or Local Codes.
Installations in the USA which employ the fans must be grounded in
accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70-1987.
For more information see the Fan Kit Installation Guide included with
the fan kit.
NOTE:
If any of the original wire supplied with the appliance is replaced, it
must be replaced with the same type, or its equivalent.
Figure 27a. Wiring schematic for optional fans.
G
L2-WH
L1-BLK
p g
Quick Connect
lu to motor
5/1/60 Supply
G
L1 L2
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Junction Box
115VAC
24VAC
40 VA
Transformer
Black
White
Green
Gnd Screw
Wall Switch
Fan Plug
Receptacle