beautypg.com

Installation, Converting to top vent/ rear vent – Montigo HT34 PV User Manual

Page 7

background image

Page 7

HT34-PV Series Power Vent Gas Fireplace

Part No. XG0530 - 041510

Installation

Converting to Top Vent/ Rear Vent

HT34-PV Top Vent

Use the following instructions to convert an HT34-PV for Top Vent use:

1. Install the 4" inner flue cap on the rear flue outlet and secure the

cap in place with five screws, as shown in figure 7a.

2. Install the flue gasket material and flue cover plate on the rear vent

outlet . Fasten the plate with four screws, as illustrated below.

3. Install the 4" inner flue collar and the 7" outer flue collar in place

on the top vent outlet using 5 screws, as illustrated below.

Figure 7a.

Flue cap installation for Top Vented fireplace.

Figure 7b.

Flue collar installation for Top Vented fireplace.

Figure 8a.

Flue cap installation for Rear Vented fireplace.

Figure 8b.

Flue collar installation for Rear Vented fireplace.

4” Inner Flue Cap

7” Outer Flue Cap

HT34-PV Rear Vent

Use the following instructions to convert an HT34-PV for Top Vent use:

1. Install the 4" inner flue cap on the top flue outlet and secure the

cap in place with five screws, as shown in figure 8a.

2. Install the 7" outer flue cap on the top flue outlet, and secure it

with five screws, as shown in figure 8a.

4” Inner Flue Collar

7” Outer Flue Collar

4” Inner Flue Cap

7” Outer Flue Cap

4” Inner Flue Cap

7” Outer Flue Cap

4” Inner Flue Cap

7” Outer Flue Cap

7” Outer Flue Collar

4” Inner Flue Collar

3. Install the flue gasket material and flue cover plate on the top

vent outlet. Fasten the plate with four screws as illustrated in

Figure 8b.

4. Install the 4" inner flue collar and the 7" outer flue collar in

place on the rear vent outlet using five screws as illustrated

below.