HT34-PV Series Power Vent Gas Fireplace

Part No. XG0530 - 041510

Installation

Installing The Fireplace Shell

The fireplace may be installed in any location that maintains proper clear-

ances to air conditioning ducts, electrical wiring and plumbing. Safety,

as well as efficiency of operation, must be considered when selecting

the fireplace location. Try to select a location that does not interfere

with room traffic, has adequate ventilation, and offers an accessible

pathway for Power Vent installation. Refer to page 4 - Vent Installation

for more information.
The fireplace dimensions for HT34-PV models are shown below:

When installing a shelf over the top of the fireplace, the following

guidelines must be adhered to: For Rear Vent applications the

minimum clearance from the top of the fireplace to a shelf is 9". For

Top Vent applications, the minimum clearance is 17 1/2". (Minimum

2" clearance must still be maintained around the vent pipes.)

Figure 4.

Framing for shelves over the fireplace.

Top Vent

Figure 3.

Minimum Corner framing dimensions, using a 45° elbow.

Figure 2.

Framing dimensions.

* When sheetrock is
not used behind the
fireplace, framing
depth may be reduced
by 5/8"

Framing

Top View

Front View

Side View

Clearances

These clearances apply to all dimensions except the framed opening,

where the clearance to combustibles is 0". The HT34-PV Series

clearances to combustible materials are:

Unprotected combustible walls which are perpendicular to the fireplace

opening, must not project beyond the shaded area shown in Figure 25.
For protection against freezing temperatures, it is recommended that

outer walls of the chase be insulated with a vapor barrier. This will reduce

the possibility of a cold-air convection current on the fireplace.

Figure 1.

Fireplace dimensions.

Rear Vent

* Clearances from the top of the fireplace to a combustible ceiling

within the fireplace enclosure.

** Refer to page 14.

WARNING!

When this appliance is installed directly on carpeting, tile or any

combustible material other than wood flooring, it must be installed

on a metal or wood panel extending the full width and depth of

the appliance.

52 5/8”

34”

37 3/8”

0” clearance to

corners only

20”

53 3/4”

34”

Note: PV venting Not exactly as shown.

17 3/8”

48”

7”

4”

40 1/4”

47 3/8”

47 7/8”

1 1/4”

1”

31 3/8”

Opening

1 1/4

1 1/4”

5 1/2”

5 1/4”

37 1/8”

Opening

17 3/8”

22”

9 1/2”

CL

7”

4”

33 7/8”

M

T

9”

S

Header

Header

Shelf

MEL Short

Shelf

L

M

17 1/2”

Power Vent

HT34-PV

Top - Rear Vent *

9"

Top - Top Vent

17 1/2”

Back

2"

Sides

1"

Floor

0"

Mantle**