Installation – Montigo RX200 User Manual
Page 4
Installation
Page 4
XT0016 - 092214
B. Stepper Motor Installation:
1. Using a Torx T20 or slotted screw driver, remove the two screws
that are attached to the Hi-Low knob on the Gas Control Valve
(Figure 7) and discard the screws and the knob. Remove gas-
ket and discard.
2. Ensure the prefitted rubber gasket is properly positioned
(Figure 10 - D). Otherwise, fit the gasket as shown.
4. Manually thread the two
supplied mounting screws into
the valve body. Use a torque screw driver with Torx T20
bit, to tighten the two screws to a torque setting of of 25
lb-in +/- 5%.
5. Install the enclosed identification label to the valve body
Figure 11 - G.
Figure 7
Replace Hi-Lo knob on valve
Figure 8
Stepper Motor - LP
3. Position the stepper motor on the gas control valve as
shown in
Figure 11 - E.
Figure 9
Stepper Motor - NG
Figure 10
Stepper Motor Installations
Figure 11
Label Installation
Figure 12
Identification Label - NG
Figure 13
Identification Label - LP