beautypg.com

Installation – Montigo RX200 User Manual

Page 4

background image

Installation

Page 4

XT0016 - 092214

B. Stepper Motor Installation:
1. Using a Torx T20 or slotted screw driver, remove the two screws

that are attached to the Hi-Low knob on the Gas Control Valve

(Figure 7) and discard the screws and the knob. Remove gas-

ket and discard.

2. Ensure the prefitted rubber gasket is properly positioned

(Figure 10 - D). Otherwise, fit the gasket as shown.

4. Manually thread the two

supplied mounting screws into

the valve body. Use a torque screw driver with Torx T20
bit, to tighten the two screws to a torque setting of of 25
lb-in +/- 5%.

5. Install the enclosed identification label to the valve body

Figure 11 - G.

Figure 7

Replace Hi-Lo knob on valve

Figure 8

Stepper Motor - LP

3. Position the stepper motor on the gas control valve as

shown in

Figure 11 - E.

Figure 9

Stepper Motor - NG

Figure 10

Stepper Motor Installations

Figure 11

Label Installation

Figure 12

Identification Label - NG

Figure 13

Identification Label - LP