Installation – Montigo H38DF-CLCR User Manual
Page 8
Page 8
XG0213 - 150204.2
H*38DF-CLCR Corner Gas Fireplace
Installation
Section 2: Framing the Fireplace
Frame in the enclosure for the unit with framing materials. The framed
opening for the assembled fireplace is 48 " wide, 44 " high, 25 1/4"
deep, see Figure 2.
NOTE: When constructing the framed opening, please ensure
there is access to install the gas line when the unit is installed�
See Figure 21.
Figure 2. Framing dimensions.
Figure 3� Combustible Framing for shelves over the unit. Top vent.
Figure 4� Combustible Framing for shelves over the fireplace, Rear vent.
48”
25¼”
*43 ¾”
48”
25¼”
*43 ¾”
H38DF CL Corner Left
H38DF CR Corner Right
* = Approximate Dimensions to center
For best results mount non-combustible stud onto unit
prior to installation, then bolt to 2 X 4 header and floor.
Non combustible
stud included with unit.
44”
44”
Figure 5� Non Combustible Framing with alcove above fireplace, Top Vent.
48”
25¼”
*43 ¾”
48”
25¼”
*43 ¾”
H38DF CL Corner Left
H38DF CR Corner Right
* = Approximate Dimensions to center
For best results mount non-combustible stud onto unit
prior to installation, then bolt to 2 X 4 header and floor.
Non combustible
stud included with unit.
44”
44”
Combustible Shelf
46”
Min.
44”
Exterior
Wall
90 elbow
1” Min.
4” Nailing flange or
Non-combustible material
17 1/2”
Min.
Combustible Header
Combustible
Shelf
59”
Min.
44”
Exterior
Wall
18”
Max.
90 elbow *
See Note:
Combustible
Header
1” Min.
90 elbow
1” Min.
4” Nailing flange or
Non-combustible material
13”Min.
Floor
39 5/8”
44”
Combustible
Header
Min. 1 ”
2”
Ceiling level
Non-Combustible
Header
Non-Combustible
materials. Alcove
over fireplace.
Top Vent
Non-Combustible
Materials, with Low
profile mantel / Alcove
over fireplace.
84”
min.
Note: Images are shown without screens for clarity purposes. However,
your fireplace should not be operated without proper installation of