Section 2: framing, Installation – Montigo H42DF ST User Manual

Page 8

background image

H*42DF ST Indoor Gas Fireplace

Page 8

XG0237 - 150204.1

Installation

Section 2: Framing

1).

Frame in the enclosure for the unit with framing materials. The framed

opening for the assembled fireplace is 45" wide, x 49½" high x 24"

deep, see Figure 2

.

NOTE: When constructing the framed opening, please ensure there is

access to install the gas line when the unit is installed. See Figure 19.

Figure 2. Framing dimensions, (Both Sides Typical).

Figure 4. Combustible Framing for shelves over the fireplace, Top vent.

Figure 5. Non Combustible Framing with alcove above fireplace,

Right side. Combustible Framing above fireplace, Left side, see

figure 2. (Top Vent).

Floor

Combustible

Header

Min. 1”

Ceiling level

Non-Combustible

Header

Non-Combustible

materials. Alcove

over fireplace.

Non-Combustible Nail-

ing Flange, (supplied).

Both sides Typical.

See figure

Top Vent

49½"

40½"

10”

6"

Figure 3. Securing the fireplace to the framing cleats.

Frame the fireplace cavity according to Figure 2.

„

Slide the fireplace into the cavity.

„

Tack four studs (Vertical, "broken line") in place, shown in Fig 3.

„

Secure the fireplace in position by nailing into these cleats.

6.

45”

(rough opening)

24”

49½”

46½”

Both walls Typical. May

not be exactly as shown.

Combustible material

Backframe, 2-pieces. Both

Sides Typical. See figure 3.

Non-Combustible

headers (Supplied).

PEL Short

90 elbow

Combustible material Backframe,

2-pieces. Both Sides Typical

Combustible Header

Non-Combustible Header

Combustible Shelf

50"

46½"

19"

f

Flex or Rigid

Insulated Sleeve

CRS101

MIN to

shel

49½”

to 1st combustible

Stud

Note: Images are shown without screens for clarity purposes. However,

your fireplace should not be operated without proper installation of

screens.

45”