beautypg.com

Section 6: finishing, Notice, Installation – Montigo H42DF ST User Manual

Page 21: Warning

background image

H*42DF ST Indoor Gas Fireplace

Page 21

XG0237 - 150204.1

Installation

Section 6: Finishing

6”

6”

3

Drywall/

Sheetrock

Non-Combustible

Header

Non-Combustible

Facing Material

Figure 20. Combustible mantels and facings.

Finishing Around the Fireplace

Combustible mantels and mouldings may be safely installed over the

top and on the front of the fireplace provided that they do not project

beyond shaded area shown in Figure 20.

Fireplace Facing

When sizing the finish material for your fireplace, it is important to

remember the following: THE OPENING MUST NOT BE OBSTRUCTED

IN ANY WAY - to do so restricts the air supply for the control

compartments and heat exchanger it also prevents access for

servicing controls.
The face of the fireplace may be painted to match the room decor,

provided you use a heat-resistant paint. Decorative facing must not

extend past the fireplace opening at all, because it will interfere with

the access to retainers for removal of glass door.

Mantels & Surrounds

NOTE: National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the

wise use of energy, has prompted us to manufacture many models of

fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal

room temperature and walls above fireplace may be hot to touch.

Side wall clearances are 3". Combustible surrounds may be installed

with 3" clearance to the side of the fireplace as shown in Figure 21.

Do not operate this fireplace without the glass door or with a broken glass door.

NOTICE

Do not use ammonia based or abrasive cleaners on the glass, they will permanently

etch the surface. Use an approved gas fireplace glass cleaner such as Kel-Kem or

White off.

NOTICE

Figure 21. Combustible surrounds. Typical both sides.

WARNING!

We recommend careful consideration be given to the effects of

elevated mantel temperatures which may be in excess of product

design, for example: candles, plastic or pictures. This can cause

melting, deformation, discolouration or premature failure of T.V.

radio, and other electronic components.

WARNING!

When covering the upper metal portion of the fireplace, up to 4"

(as shown, Fig.20) with a non-combustible material Please Note:

The decorative facing materials may be subject to temperatures

in excess of 250° F. This should be considered when selecting

facing materials.

Top of fireplace

Non-Combustible

Combustible Facing

Material

Facing Material

Steel Stud construction only

allowed within the grey area

Horizontal Run (in.)

Vertical Height (in.)

NON-Combustible

Header

1st combustible header

Combustible Construction

allowed in shaded area

WARNING

Do not place any materials or objects on top of the

valve blind. Doing so could result in failure of door

relief system or heat dissipation.

This manual is related to the following products: