Panasonic, Pa-1 – MK Products Weld Control User Manual
Page 30
Weld Control Selector Guide - Page 23
Panasonic
PA-1
The Gunslinger 260 kit (P/N 005-0617) plugs directly into the amphenol on the front of the unit.
The lug on the power cable of the Prince XL Spool-gun will be hooked up to the positive (+) terminal of
the welder. It is inside the door housing the unit's wire feeder, just under the feeder.
A Cobramatic Cabinet may be hooked up to the Gunslinger 260 as follows:
1. Plug the 115VAC plug extending from the Cobramatic Cabinet into a standard wall outlet.
2. Connect the
black and white contactor leads of the Cobramatic Cabinet to pins 1 and of the
Spool-gun plug on the front of the Gunslinger 260. Place the contactor on the Cobramatic in the
CLOSING CONTACTS position (see Appendix for contactor information).
3. Even though you're operating a Cobramatic push-pull system instead of a spool-gun, the
Gunslinger 260 must have the Mode Plug inserted into the Spool-gun location. The power cable
to the Cobramatic would be hooked up to positive (+) terminal which is just under the units wire
feeder inside the door.
4-Pin aMP
MK P/n’s
aMP P/n’s
Socket
153-0998
206429-1
Cord Clamp
153-0946
206062-3
Pins (2 req.)
153-0958
66099-2/-3