Esab, Includes l-tec & linde) – MK Products Weld Control User Manual
Page 17
Weld Control Selector Guide - Page 10
ESaB
(includes L-tec & Linde)
The older Linde CV machines are connected as follows:
1. Connect the
black and white contactor leads extending from the WC-1 Weld Control or the
Cobramatic Cabinet to the 6-Pin metal Pyle-National plug;
black to pin 3 and white to pin 5.
Place WC-1 or Cobramatic in the 115VAC CONTACTOR position (See Appendix for changing
contactor).
2. Plug the 115VAC plug extending from the WC-1 or Cobramatic into a standard wall outlet or
cut off the plug and wire the
black wire to pin 1, the white wire to pin 2 and the
green wire to pin 4.
3. Tape off WC-1
red and green leads and turn off Posa Start switch as
Posa Start is not used.
The newer ESAB/Linde/L-Tec CV machines are connected as follows:
1. Connect the
black and white contactor leads extending from the WC-1 Weld Control or
Cobramatic Cabinet to the 7-Pin plastic AMP plug;
black to pin 1 and white to pin 3. Place WC-
1 or Cobramatic in the CLOSING CONTACTS position (see Appendix for contactor information).
2. Plug the 115VAC plug extending from the WC-1 or Cobramatic into a standard wall outlet or
cut off the plug and wire the
black wire to pin 1, the white wire to pin 2 and the green
wire to
pin 4.
3. Tape off WC-1
red and green leads and turn off Posa Start switch
as Posa Start is not used.
Some ESAB/L-TEC CV/CC machines have 19 pin (J1) amphenols and are connected as follows:
1. Connect the
black and white contactor leads extending from the
WC-1 or the Cobramatic to the 19 pin amphenol plug;
black to pin
a and white to pin C. Place WC-1 or Cobramatic in the CLOSING
CONTACTS position (see Appendix for contactor information). Pins
U & V can also be used for contactor.
2. Plug the 115VAC plug extending from the WC-1 or Cobramatic into a
standard wall outlet or cut off the plug and wire the
black wire to pin
a, the white wire to pin B and the green wire to pin d.
The MultiPower 460 units do not supply 115VAC at the 19-Pin.
3. Tape off WC-1
red and green leads and turn off Posa Start switch as Posa Start is not used. On
the Cobramatic System hook up the Posa-Start lead to the Power Supplies ARC GROUND and
use PosaStart when welding aluminum only.
E-5
note: Use in CV-Mig mode and be
sure that nothing is plugged
into J2 (8-Pin).
A
B
C
D
E
H
J
K
L
M
N
P
R
S
T
U
V
F
G
BL
AC
K
W
H
IT
E
Con
tac
tor
Cor
d
BLACK
WH
ITE
G
R
E
E
N
115VAC
Leads
P/N 005-0614
Complete 8' cable with 19P Amphenol attached.
Easily connects to SVI 450 (115VAC on 19-Pin).
Pyle national “triploc”
Male Plug
AP-610
Housing
APD-2004
7-Pin amp Connector
L-Tec P/N
AMP P/N
7-Pin Plug
674655
206226-1
Cord Clamp
674568
206138-1
Pins (4 req.)
674564
66255-1
E-6
19-Pin amphenol
MK P/N’s
Amphenol P/N’s
19-Pin Plug
153-0314
3106A22-14P
Cord Clamp
411-0035
3057-1012
Rubber Boot
301-0026