The older Linde CV machines are connected as follows:

1. Connect the

black and white contactor leads extending from the WC-1 Weld Control or the

Cobramatic Cabinet to the 6-Pin metal Pyle-National plug;

black to pin 3 and white to pin 5.

Place WC-1 or Cobramatic in the 115VAC CONTACTOR position (See Appendix for changing

contactor).

2. Plug the 115VAC plug extending from the WC-1 or Cobramatic into a standard wall outlet or

cut off the plug and wire the

black wire to pin 1, the white wire to pin 2 and the

green wire to pin 4.

3. Tape off WC-1

red and green leads and turn off Posa Start switch as

Posa Start is not used.

The newer ESAB/Linde/L-Tec CV machines are connected as follows:

1. Connect the

black and white contactor leads extending from the WC-1 Weld Control or

Cobramatic Cabinet to the 7-Pin plastic AMP plug;

black to pin 1 and white to pin 3. Place WC-

1 or Cobramatic in the CLOSING CONTACTS position (see Appendix for contactor information).

2. Plug the 115VAC plug extending from the WC-1 or Cobramatic into a standard wall outlet or

cut off the plug and wire the

black wire to pin 1, the white wire to pin 2 and the green

wire to

pin 4.

3. Tape off WC-1

red and green leads and turn off Posa Start switch

as Posa Start is not used.

Some ESAB/L-TEC CV/CC machines have 19 pin (J1) amphenols and are connected as follows:

1. Connect the

black and white contactor leads extending from the

WC-1 or the Cobramatic to the 19 pin amphenol plug;

black to pin

a and white to pin C. Place WC-1 or Cobramatic in the CLOSING

CONTACTS position (see Appendix for contactor information). Pins

U & V can also be used for contactor.

2. Plug the 115VAC plug extending from the WC-1 or Cobramatic into a

standard wall outlet or cut off the plug and wire the

black wire to pin

a, the white wire to pin B and the green wire to pin d.

The MultiPower 460 units do not supply 115VAC at the 19-Pin.

3. Tape off WC-1

red and green leads and turn off Posa Start switch as Posa Start is not used. On

the Cobramatic System hook up the Posa-Start lead to the Power Supplies ARC GROUND and

use PosaStart when welding aluminum only.

E-5

note: Use in CV-Mig mode and be

sure that nothing is plugged

into J2 (8-Pin).

A

B

C

D

E

H

J

K

L

M

N

P

R

S

T

U

V

F

G

BL

AC

K

W

H

IT

E

Con

tac

tor

Cor

d

BLACK

WH

ITE

G

R

E

E

N

115VAC
Leads

P/N 005-0614

Complete 8' cable with 19P Amphenol attached.

Easily connects to SVI 450 (115VAC on 19-Pin).

Pyle national “triploc”

Male Plug

AP-610

Housing

APD-2004

7-Pin amp Connector

L-Tec P/N

AMP P/N

7-Pin Plug

674655

206226-1

Cord Clamp

674568

206138-1

Pins (4 req.)

674564

66255-1

E-6

19-Pin amphenol

MK P/N’s

Amphenol P/N’s

19-Pin Plug

153-0314

3106A22-14P

Cord Clamp

411-0035

3057-1012

Rubber Boot

301-0026