Weld Control Selector Guide - Page 14

The WC-1 Weld Control or the Cobramatic Cabinet can be connected to the SP-250 as follows:

1. Remove the left side panel of SP-250.

2. Splice the

black and white contactor leads from the WC-1 or

Cobramatic to the J5 plug located below the wire feed motor;

black to # 325 and white to # 324. Place the contactor in the

CLOSING CONTACTS position (see Appendix for contactor

information).

3. Plug the 115VAC plug from the WC-1 or Cobramatic into a

standard wall outlet.

4. Tape off WC-1

red and green leads and turn off Posa Start switch

as Posa Start is not used.

5. Set the unit on "MANUAL" and adjust the voltage using the "UP &

DOWN" push-button.

The PA-G1 Control (P/N 005-0264) can also be connected to the SP-250 as follows:

1. Remove the left side panel of SP-250

2. Splice the

red and green contactor leads extending from the

Control to the J5 plug located below the wire feed motor;

red to

wire

# 325 and green to # 324. The trigger plug on the SP-250

front panel can also be used.

3. Remove the right side panel of the SP-250 and locate red wires

# 202 and # 203 going to plug # J6 on the main P.C. board.

4. Splice the

black wire extending from the Control to wire # 202 and

the

white wire to # 203.

5. Set the unit on "MANUAL" and adjust the voltage using the "UP &

DOWN" push-button.

Lincoln Electric

note: The feeder inside the SP-250 will also be

turned on so disengage the spring tension on

the drive roll.

four Pin Plug

Cinch-Jones P/N P-304

Lincoln P/N T-10662-1

Splice Connectors

MK P/N 153-0818

3M P/N 558 (2 req'd)

L-1

notes: 1. Proper operation of the PA-G1 kit is

dependant upon the correct input voltage

value.

2. Four of the 153-0818 splice connectors are

included in the PA-G1 Control kit.

Splice Connectors

MK P/N 153-0818

3M P/N 558 (4 req'd)

The SP-150 & 200 are interfaced using the WC-1 Weld Control or the Cobramatic Cabinet as follows:

1. Connect the

black and white contactor leads extending from the WC-1 or

Cobramatic to the 4-Pin plug located below the wire feed motor. Place the

contactor in the CLOSING CONTACTS position (see Appendix for contactor

information).

2. Plug the 115VAC plug extending from the WC-1 or Cobramatic into a

standard wall outlet (in some cases 115VAC can be found at the fan motor).

3. Tape off WC-1

red and green leads and turn off Posa Start switch as Posa

Start is not used.

L-2