beautypg.com

Esab, E-2 e-3 e-4 – MK Products Weld Control User Manual

Page 16

background image

Weld Control Selector Guide - Page 9

ESaB

(includes L-tec & Linde)

The 005-0206 Kit will interface a Prince XL Spool-gun to a Migmaster 250. It plugs directly into the

amphenol on the front of the unit and includes everything needed to interface to that power supply.

A Cobramatic system may be used on this unit and would be interfaced as

follows:

1. Plug the 115VAC plug from the Cobramatic Cabinet into a standard

wall outlet.

2. Connect the

black and white contactor leads from the Cobramatic

Cabinet to the 8-Pin (Spool-gun) plug on the Migmaster 250:

the

black wire to Pin a and the white wire to Pin B. Put the

Cobramatic in CLOSING CONTACTS Position (see Appendix for

contactor information).

E-1

The 005-0624 Kit will interface a Prince XL Spool-gun to a Migmaster 251. It replaces a blank

panel on the front of the machine and includes everything needed to interface to this welder.

A Cobramatic system may be used on this unit and would interface as follows:

1. Plug the 115VAC plug from the Cobramatic Cabinet into a standard wall outlet

2. Install 1/4 (.250) wide female spade connectors to the

Black and White contactor wires extending

from the Cobramatic Cabinet to the male spade connectors located on the inside wall of the

welder by the wire feeder. First remove the existing trigger leads from the Migmaster torch. Place

the Cobramatic in the CLOSING CONTACTS position (see Appendix for contactor information).

3. Place the power cable lug from the Cobramatic Cabinet on the positive ( + ) terminal of the

Migmaster 251 located by the wire feeder inside the welder.

The older L-Tec 225 is connected as follows:

1. Install 1/4 (.250) wide female spade connectors to the

Black and White contactor wires extending

from the WC-1 Weld Control or the Cobramatic Cabinet to the male spade connectors located on

the inside wall of the welder by the wire feeder. First remove the existing trigger leads from the L-

Tec torch. Place the WC-1 or Cobramatic in the CLOSING CONTACTS position (see Appendix for

contactor information).

2. Plug the 115VAC plug extending from the WC-1 or Cobramatic into a standard wall outlet.

Note: The feeder inside this unit will also be activated so disengage the spring tension on

the drive roll.

The WC-1 Weld Control of the Cobramatic Cabinet may be connected to the Migmaster 300 as follows:

1. Plug the 115VAC plug from the WC-1 Weld Control of the Cobra

Cabinet into a standard wall outlet.

2. Connect the

Black and White contactor leads from the WC-1 or

Cobramatic to the 8-Pin plug on the Migmaster 300. The

black

wire to

Pin a and the white wire to Pin B. Put the WC-1 or

Cobramatic into CLOSING CONTACTS position (see Appendix for

contactor information).

3. A male Dinse style connector is required on this machine. Cut the

lug off of the power cable on the Prince XL Spool-gun and replace

with the Dinse connector.

note - The power cable to the Cobramatic hooks to bolt holding an

existing cable just in front of the MM-250's wire feed motor. Place the

Switch (Std/Spool-gun) in Spool-gun position.

E-2

E-3

E-4

8-Pin amphenol

Socket

153-0922

Cord Clamp

411-0191

Rubber Boot

301-0054

8-Pin amphenol

Socket

153-0922

Cord Clamp

411-0191

Rubber Boot

301-0054

DInse Connector

Male Plug

153-0755